Honeywell’s high capacity, feature-rich VISTA-21iP lets you deliver more value to your customers on each and every sale. The VISTA-21iP provides up to 48 zones of protection, an on-board IP connection, graphic keypad support and dual partitions. The VISTA-21iP gives you the ability to send alarm signals and upload/download via an Internet Protocol (IP), improving the speed at which information can be delivered to and from the control panel. When used with an optional AlarmNet® GSM that snaps right on the board, the VISTA-21iP can be installed in premises without TELCO lines – guaranteeing communication independent of any infrastructure. The panel’s installation advantages, innovative end-user benefits and robust system capacity make the value-priced VISTA-21iP an ideal choice for higher-end installations.
Honeywell’s high capacity, feature-rich VISTA-21iP lets you deliver more value to your customers on each and every sale. The VISTA-21iP provides up to 48 zones of protection, an on-board IP connection, graphic keypad support and dual partitions. The VISTA-21iP gives you the ability to send alarm signals and upload/download via an Internet Protocol (IP), improving the speed at which information can be delivered to and from the control panel. When used with an optional AlarmNet® GSM that snaps right on the board, the VISTA-21iP can be installed in premises without TELCO lines – guaranteeing communication independent of any infrastructure. The panel’s installation advantages, innovative end-user benefits and robust system capacity make the value-priced VISTA-21iP an ideal choice for higher-end installations.
More Information
Manufacturer Part Number
21IP
Features
Features
Internet alarm reporting and uploading/downloading capability via on-board AlarmNet Internet Communicator
Supports four graphic touchscreen keypads
Wireless keys can be programmed without using zones
Eight on-board hardwired zones standard (15 when Zone Doubling feature is used) – 40 hardwired expansion zones – 40 wireless expansion zones
Two low current on-board trigger outputs
100 Event Log viewable at system keypads with time/date stamp
48 system user codes assignable to either partition
Expandable to 48 total zones when used with hardwired and/or wireless expansion modules
Two independent partitions plus a common partition – Global arming from any system keypad – Goto function to view or operate one partition from the other – Separate partition account numbers
Four installer-configurable zone types allows the installer to create custom zone types by assigning all zone attributes
Supports four-wire, and up to 16 two-wire smokes – Works with Sentrol CleanMe™ maintenance signal
Multiple actions on output devices depending on system state – Turns lights off when system arms – Turns the same light on when system disarms – Flashes same lights when system is in alarm
Built-in phone line cut monitor with programmable delay and annunciation options – Display on system keypads – Trigger local sounders – Trigger system bell
Security Dealer Features
Automatic System Load Shed – During extended AC power fail, the system battery will be disconnected to prevent irreversible battery failure. Reduces service calls to replace batteries.
Dynamic Signaling – Reduces redundant reporting to the central station when multiple reporting methods are used; i.e. digital dialer and AlarmNet radio
Valuable End-User Features
Viewable on system keypads: – Exit countdown – Time and date display* – Event log*
Auto keypad backlighting on entry
Keyswitch arming
Programmable macro buttons and single-button arming
Supports a variety of wireless remote controls for single-button operation
User Scheduling – Auto arm/disarm – “User access” time windows
VIP Module allows system control from any touchtone phone
Chime by zone
*Requires custom alpha keypad
Write Your Own Review
Features
Internet alarm reporting and uploading/downloading capability via on-board AlarmNet Internet Communicator
Supports four graphic touchscreen keypads
Wireless keys can be programmed without using zones
Eight on-board hardwired zones standard (15 when Zone Doubling feature is used) – 40 hardwired expansion zones – 40 wireless expansion zones
Two low current on-board trigger outputs
100 Event Log viewable at system keypads with time/date stamp
48 system user codes assignable to either partition
Expandable to 48 total zones when used with hardwired and/or wireless expansion modules
Two independent partitions plus a common partition – Global arming from any system keypad – Goto function to view or operate one partition from the other – Separate partition account numbers
Four installer-configurable zone types allows the installer to create custom zone types by assigning all zone attributes
Supports four-wire, and up to 16 two-wire smokes – Works with Sentrol CleanMe™ maintenance signal
Multiple actions on output devices depending on system state – Turns lights off when system arms – Turns the same light on when system disarms – Flashes same lights when system is in alarm
Built-in phone line cut monitor with programmable delay and annunciation options – Display on system keypads – Trigger local sounders – Trigger system bell
Security Dealer Features
Automatic System Load Shed – During extended AC power fail, the system battery will be disconnected to prevent irreversible battery failure. Reduces service calls to replace batteries.
Dynamic Signaling – Reduces redundant reporting to the central station when multiple reporting methods are used; i.e. digital dialer and AlarmNet radio
Valuable End-User Features
Viewable on system keypads: – Exit countdown – Time and date display* – Event log*
Auto keypad backlighting on entry
Keyswitch arming
Programmable macro buttons and single-button arming
Supports a variety of wireless remote controls for single-button operation
User Scheduling – Auto arm/disarm – “User access” time windows
VIP Module allows system control from any touchtone phone