Dry Contact Board for PIM400-T
RLBD Schlage Electronics Integrated and Pushbutton
Description
Speicfications
| Series | AD Series Networked Electronic Locks |
|---|---|
| Vendor | Allegion |
| Manufacturer | Schlage Electronics |
| Installation | Commercial |
Details
AD-400 locks feature upgradeable credential reader modules and real-time integration with most access control system.
Security
- Electronic access control brings more visibility and control to the opening
- Modular design allows reader upgrade to fit changing credential needs without changing the lock
- Real-time communication with centralized lockdown capability
- Unique communication protocols that has a longer range and won’t interfere with other wireless networks
- Secure encrypted data transmission
- Weather-resistant for interior and perimeter applications
Efficiency
- Open architecture platform is compatible with most major access control systems
- Flexible connectivity options to fit building infrastructure
Convenience
- Integrated design combines electrified lock, credential reader, request-to-exit and request-to-enter sensors, door position switch and tamper switch
- Smart credentials can be used for vending and other applications
- Non-invasive installation
AD Series locks were designed to be adaptable, allowing upgrades to be made to new technologies without taking the lock off the door. They integrate into popular electronic access control systems from Software Alliance Members to deliver a comprehensive EAC solution.
Available in cylindrical, mortise, mortise deadbolt and exit trim chassis options, they feature built-in credential reader and access control sensors for simplified installation.
The AD-400 enables a wide range of credential options including NFC mobile, smart (13.56 MHz), proximity (125 kHz), magnetic stripe and PIN credentials; card + PIN is also available for extra security.
AD-400 locks communicate using 900 MHz wireless technology to the PIM400, operating independently of the IT network. For real-time connectivity and lockdown, the PIM400 is wired to the access control panel (ACP) either by Wiegand or RS-485. AD-400 wireless locks can work in the same access control system as other wireless devices including Schlage NDE, LE, and the WRI400. Features and capabilities will vary by system; please see the Software Alliance Members tab for additional details.
Instructions
- Mechanical Installation Manuals AD-Series Cylindrical
- Mechanical Installation Manuals AD-Series Exit
- Mechanical Installation Manuals AD-Series Exit Mortise
- Mechanical Installation Manuals AD-Series Mortise
- User Guide AD-400 & AD-401 English
- User Guide AD-400 French
- User Guide AD-400 Spanish
- AD-Series Remote Access Antenna Grounding Block Kit Instructions
- User Guide AD-300 French
- User Guide AD-300 Spanish
- User Guide AD-250 English
- User Guide AD-250 French
- User Guide AD-250 Spanish
- User Guide AD-200 French
- User Guide AD-200 Spanish
- User Guide AD-200/AD-201 English
- AD-Series REPTR400-TD2 Repeater Installation Manuals
- Schlage AD300 AD400 Wiring Diagram Johnson Controls S321-IP Wiegand
- Schlage AD300 AD400 Wiring Diagram Johnson Controls RDR2S-A Wiegand
- Schlage AD400 Wiring Diagram Quintron PIM400-1501 RS485
- Schlage AD300 AD400 Wiring Diagram Schneider ACX5720/40 RS485
- Schlage AD300 AD400 Wiring Diagram Schneider Netcontroller II RS485
- Schlage AD-400 PIM400-485 Wiring Diagram with Keri Systems Doors.Net Mercury ...
- Schlage AD400 Wiring Diagram Identicard PremiSys IP Controller RS485
- Schlage AD400 Wiring Diagram UTC-Casi M5 M3000 8RP WIU-4 Wiegand
- Schlage AD400 Wiring Diagram UTC-Casi M5 M3000 2SRP Wiegand
- Schlage AD400 Wiring Diagram UTC-Casi Micro PX-2000 WIU-2 Wiegand
- Schlage AD400 Wiring Diagram UTC-Casi M5 M3000 2RP Wiegand
- Schlage AD400 Wiring Diagram UTC-Casi DirecDoor Wiegand
- Schlage AD300 AD400 Wiring Diagram Blackboard SA3000 RS485
- Schlage AD300 AD400 Wiring Diagram RedCloud EP1502 Wiegand Model
- Schlage AD300 AD400 Wiring Diagram RedCloud EP2500 MR50 Wiegand Model
- Schlage AD400 Wiring Diagram RedCloud EP2500 MR52 Wiegand Model
- Schlage AD400 Matrix EP2500 RS485 Wiring Diagram
- Schlage AD400 Matrix UBC RCM2 Wiegand Wiring Diagram
- Schlage AD400 Matrix EP1502 Wiegand Model Wiring Diagram
- Schlage AD300 AD400 Wiring Diagram Galaxy 600/635 DPI Wiegand Wiring Diagram
- Schlage AD300 AD400 Wiring Diagram Johnson Controls EP-2500 RS485
- Schlage AD AD400 Wiring Diagram Johnson Controls WRI-400 PIM400-1501 RS485
- Schlage AD400 Wiring Diagram CBord V1000RX RS485
- Schlage AD300 AD400 Wiring Diagram Badgepass BAC042500 RS485
- Video: AD Series Cylindrical Electrical Hook Up Instructions
- Video: AD Series - How to Rehand Mortise Electronic Lock
- Video: AD Series Exit Trim Installation
- Video: AD Series Cylindrical Electronic Lock Installation
- Video: AD Series Mortise Electronic Lock Door Prep Instructions
- Video: AD Series - How to Rehand Cylindrical Electronic Lock
- Video: AD Series Mortise Electronic Locks Installation
- Video: AD Series Mortise Electrical Hook Up Instructions
- Video: AD Series Exit Trim - How to Re-Hand
- Schlage AD300/AD400 Communication Module Replacement Kit Installation Instructions
- Schlage Tailpiece Kit for Falcon 6-Pin Cylinder AD/CO Series Locks Installation Instructions
- Schlage AD Series Optional Relay Board (RLBD) Installation Instructions
- Schlage AD Series RX-LC Switch Retrofit Installation Instructions
- Schlage AD Series PIM400-1501-LC Installation Instructions
- Schlage AD Series FCC IC Compliance Statement
- Schlage AD Series Reader Replacement Installation Instructions
- Schlage AD/CO Series Battery Kit Installation
- Schlage AD993 Series Lock 98/99 Exit IPB Installation Instruction
- Schlage AD/CO Series Lever Conversion Kit Installation Instructions
- Schlage AD/CO Series 7-Pin KIL Tailpiece Instructions
- Schlage JD Yale Lever for AD-/CO-Series Installation Instructions